Definitions and Scope
1.1. A Home inspection is a non-invasive visual examination of a residential dwelling, performed for a fee, which is designed to identify observed material defects within specific components of said dwelling. Components may include any combination of mechanical, structural, electrical, plumbing, or other essential systems or portions of the home, as identified and agreed to by the Client and Inspector, prior to the inspection process. I. A home inspection is intended to assist in evaluation of the overall condition of the dwelling. The inspection is based on observation of the visible and apparent condition of the structure and its components on the date of the inspection and not the prediction of future conditions. II. A home inspection will not reveal every concern that exists or ever could exist, but only those material defects observed on the day of the inspection. 1.2. A Material defect is a condition with a residential real property or any portion of it that would have a significant adverse impact on the value of the real property or that involves an unreasonable risk to people on the property. The fact that a structural element, system or subsystem is near, at or beyond the end of the normal useful life of such a structural element, system or subsystem is not by itself a material defect. 1.3. An Inspection report shall describe and identify in written format the inspected systems, structures, and components of the dwelling and shall identify material defects observed. Inspection reports may contain recommendations regarding conditions reported or recommendations for correction, monitoring or further evaluation by professionals, but this is not required. 2. Standards of Practice
I. The inspector shall inspect from ground level or eaves: A. The roof covering. II. The inspector is not required to: A. Walk on any roof surface.
2.2. Exterior I. The inspector shall inspect: A. The
siding, flashing and trim. A. Inspect
or operate screens, storm windows, shutters, awnings, fences, outbuildings,
or exterior accent lighting. 2.3. Basement, Foundation & Crawlspace I. The inspector shall inspect: A. The
basement. A. Enter any
crawlspaces that are not readily accessible or where entry could cause
damage or pose a hazard to the inspector. 2.4. Heating I. The inspector shall inspect: A. The heating system and
describe the energy source and heating method using normal operating controls.
II. The inspector is not required to: A. Inspect or evaluate interiors of flues
or chimneys, fire chambers, heat exchangers, humidifiers, dehumidifiers,
electronic air filters, solar heating systems, solar heating systems or
fuel tanks. I. The inspector shall inspect: A. The central cooling equipment using normal operating controls. II. The inspector is not required to: A. Determine the uniformity, temperature,
flow, balance, distribution, size, capacity, BTU, or supply adequacy of
the cooling system. 2.6. Plumbing I. The inspector shall: A. Verify the presence of and identify
the location of the main water shutoff valve. A. Light or ignite pilot flames. I. The inspector shall inspect: A. The service
line. A. Insert any tool, probe or device into
the main panel, sub-panels, downstream panels, or electrical fixtures.
2.8. Fireplace I. The inspector shall inspect: A. The fireplace, and open and close
the damper door if readily accessible and operable. II. The inspector is not required to: A. Inspect the flue or vent system. I. The inspector shall inspect: A. The insulation in unfinished spaces. II. The inspector is not required to: A. Enter the attic or unfinished spaces
that are not readily accessible or where entry could cause damage or pose
a safety hazard to the inspector in his or her opinion. I. The inspector shall: A. Open and close a representative number
of doors and windows. II. The inspector is not required to: A. Inspect paint, wallpaper, window
treatments or finish treatments. 3.
Limitations, Exceptions & Exclusions I. An inspection is not technically
exhaustive. 3.2. Exclusions:
I. The inspectors are not required to determine: A. Property boundary lines or encroachments.
II. The inspectors are not required to operate: A. Any system that is shut down. III. The inspectors are not required to: A. Move any personal items or other obstructions, such as, but not limited to: 1. Throw
rugs. B. Dismantle, open, or uncover any system
or component. |
4. Glossary
of Terms
4.1. Accessible: Can be approached or entered by the inspector safely, without difficulty, fear or danger. 4.2. Activate: To turn on, supply power, or enable systems, equipment, or devices to become active by normal operating controls. Examples include turning on the gas or water supply valves to the fixtures and appliances and activating electrical breakers or fuses. 4.3. Adversely Affect: Constitute, or potentially constitute, a negative or destructive impact. 4.4. Alarm System: Warning devices, installed or free-standing, including but not limited to: Carbon monoxide detectors, flue gas and other spillage detectors, security equipment, ejector pumps and smoke alarms. 4.5. Appliance: A household device operated by use of electricity or gas. Not included in this definition are components covered under central heating, central cooling or plumbing. 4.6. Architectural Service: Any practice involving the art and science of building design for construction of any structure or grouping of structures and the use of space within and surrounding the structures or the design, design development, preparation of construction contract documents, and administration of the construction contract. 4.7. Component: A permanently installed or attached fixture, element or part of a system. 4.8. Condition: The visible and conspicuous state of being of an object. 4.9. Crawlspace: The area within the confines of the foundation and between the ground and the underside of the lowest floor structural component. 4.10. Decorative: Ornamental; not required for the operation of essential systems and components of a home. 4.11. Describe: Report in writing a system or component by its type, or other observed characteristics, to distinguish it from other components used for the same purpose. 4.12. Determine: To arrive at an opinion or conclusion pursuant to examination. 4.13. Dismantle: To open, take apart or remove any component, device or piece that would not typically be opened, taken apart or removed by an ordinary occupant. 4.14. Engineering Service: Any professional service or creative work requiring engineering education, training, and experience and the application of special knowledge of the mathematical, physical and engineering sciences to such professional service or creative work as consultation, investigation, evaluation, planning, design and supervision of construction for the purpose of assuring compliance with the specifications and design, in conjunction with structures, buildings, machines, equipment, works or processes. 4.15. Enter: To go into an area to observe visible components. 4.16. Evaluate: To assess the systems, structures or components of a dwelling. 4.17. Examine: To visually look. See Inspect. 4.18. Foundation: The base upon which the structure or wall rests; usually masonry, concrete, or stone, and generally partially underground. 4.19. Function: The action for which an item, component, or system is specially fitted or used or for which an item, component or system exists; to be in action or perform a task. 4.20. Functional: Performing, or able to perform, a function. 4.21. Home Inspection: The process by which an inspector visually examines the readily accessible systems and components of a home and operates those systems and components utilizing these Standards of Practice as a guideline. 4.22. Household Appliances: Kitchen and laundry appliances, room air conditioners, and similar appliances. 4.23. Inspect: To visually look at readily accessible systems and components safely, using normal operating controls and accessing readily accessible panels and areas in accordance with these Standards of Practice. 4.24. Inspected Property: The readily accessible areas of the buildings, site, items, components, and systems included in the inspection. 4.25. Inspector: One who performs a real estate inspection. 4.26. Installed: Attached or connected such that the installed item requires tool for removal. 4.27. Material Defect: Refer to section 1.2. 4.28. Normal Operating Controls: Devices such as thermostats that would be operated by ordinary occupants which require no specialized skill or knowledge. 4.29. Observe: To see through visually directed attention. 4.30. Operate: To cause systems to function or turn on with normal operating controls. 4.31. Readily Accessible: An item or component is readily accessible if, in the judgment of the inspector, it is capable of being safely observed without movement of obstacles, detachment or disengagement of connecting or securing devices, or other unsafe or difficult procedures to gain access. 4.32. Recreational Facilities: Spas, saunas, steam baths, swimming pools, tennis courts, playground equipment, and other exercise, entertainment or athletic facilities. 4.33. Report: A written communication (possibly including digital images) of any material defects seen during the inspection. 4.34. Representative Number: A sufficient number to serve as a typical or characteristic example of the item(s) inspected. 4.35. Safety Glazing: Tempered glass, laminated glass, or rigid plastic. 4.36. Shut Down: Turned off, unplugged, inactive, not in service, not operational, etc. 4.37. Structural Component: A component which supports non-variable forces or weights (dead loads) and variable forces or weights (live loads). 4.38. System: An assembly of various components to function as a whole. 4.39. Technically Exhaustive: A comprehensive and detailed examination beyond the scope of a real estate home inspection which would involve or include, but would not be limited to: dismantling, specialized knowledge or training, special equipment, measurements, calculations, testing, research, analysis or other means. 4.40. Unsafe: A condition in a readily accessible, installed system or component which is judged to be a significant risk of personal injury during normal, day-to-day use. The risk may be due to damage, deterioration, improper installation or a change in accepted residential construction standards. 4.41. Verify: To confirm or substantiate. Inspect items, including window and door flashings, which are not visible or readily accessible from the ground. |